Review



hplc detector gilson 156 uv detector  (Gilson Inc)


Bioz Verified Symbol Gilson Inc is a verified supplier
Bioz Manufacturer Symbol Gilson Inc manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Gilson Inc hplc detector gilson 156 uv detector
    Hplc Detector Gilson 156 Uv Detector, supplied by Gilson Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/hplc+gilson+156+uv+detector/hplc+gilson/us12264154-11561-15-18
    Average 90 stars, based on 1 article reviews
    hplc detector gilson 156 uv detector - by Bioz Stars, 2026-10
    90/100 stars

    Images

    Related Articles

    Residue:

    Article Title: Compounds and methods of use
    Article Snippet: The mixture was concentrated under reduced pressure to give a crude product, which was purified by preparative HPLC (Instrument: Gilson GX-281 Liquid Handler, Gilson 322 Pump, Gilson 156 UV Detector; Column: Waters Xbridge 150×50 mm×10 μm; Mobile phase A: H2O with 0.05% NH3—H2O (v %); Mobile phase B: MeCN; Gradient: B from 25% to 55% in 8.8 min, hold 100% B for 2 min; Flow Rate: 25 mL/min; Column Temperature: 30° C.; Wavelength: 220 nm, 254 nm) to give N-[(2S)-3-[7-chloro-6-(oxazol-5-ylmethoxy)-3,4-dihydro-1H-isoquinolin-2-yl]-2-hydroxy-propyl]-2-(cyclobutylamino)pyridine-4-carboxamide (15 mg, 17.2% yield) as a yellow dry powder.

    Article Title: HDAC inhibitors and therapeutic use thereof
    Article Snippet: The residue was purified by preparative HPLC (Instrument: Gilson GX-215, Gilson 322 Pump, Gilson 156 UV Detector; Column: Xtimate C18 150*40 mm*5 μm; Mobile phase A: H2O with NH3—H2O and NH4HCO3 (v %); Mobile phase B: MeCN; Gradient: B from 23% to 53% in 20 min, hold 100% B for 5 min; Flow Rate: 30 mL/min; Column Temperature: 30° C.; Wavelength: 220 nm, 254 nm).

    Article Title: HDAC inhibitors and therapeutic use thereof
    Article Snippet: The crude product was purified by preparative HPLC (Instrument: Gilson GX-281 Liquid Handler, Gilson 322 Pump, Gilson 156 UV Detector; Column: Phenomenex Gemini-NX 75*40 mm*3 μm; Mobile phase A: [water (NH3H2O+NH4HCO3)-ACN]; Mobile phase B: MeCN; Gradient: B from 31% to 61% in 10.5 min, hold 100% B for 2 min; Flow Rate: 30 mL/min; Column Temperature: 30° C.; Wavelength: 220 nm) to afford N-[2-amino-5-(p-tolyl)phenyl]-4-(3-methyl-1-oxo-4,5-dihydro-3H-isothiazol-1-yl)benzamide (45 mg, 70.2% yield) as white solid.

    Article Title: HDAC inhibitors and therapeutic use thereof
    Article Snippet: The residue was purified by preparative HPLC (Instrument: Gilson GX-281 Liquid Handler, Gilson 322 Pump, Gilson 156 UV Detector; Column: Durashell 150×25 mm×5 μm; Mobile phase A: H2O with 0.05% NH3—H2O (v %); Mobile phase B: MeCN; Gradient: B from 39% to 69% in 10 min, hold 100% B for 2.5 min; Flow Rate: 25 mL/min; Column Temperature: 30° C.; Wavelength: 220 nm, 254 nm) to afford N-[2-amino-5-(4-chlorophenyl)phenyl]-4-(methylsulfonimidoyl)benzamide (15.8 mg).

    Article Title: HDAC inhibitors and therapeutic use thereof
    Article Snippet: The residue was purified by preparative HPLC (Instrument: Gilson GX-281 Liquid Handler, Gilson 322 Pump, Gilson 156 UV Detector; Column: Phenomenex Gemini-NX 80×40 mm×3 μm; Mobile phase A: water with 10 mmol NH4HCO3 (v %); Mobile phase B: MeCN; Gradient: B from 27% to 57% in 7.8 min, hold 100% B for 1 min; Flow Rate: 25 mL/min; Column Temperature: about 30° C.; Wavelength: 220 nm, 254 nm) to afford N-[2-amino-5-(2-thienyl)phenyl]-4-(cyclopropylsulfonimidoyl)benzamide (about 61.7 mg).

    Purification:

    Article Title: Compounds and methods of use
    Article Snippet: The mixture was concentrated under reduced pressure to give a crude product, which was purified by preparative HPLC (Instrument: Gilson GX-281 Liquid Handler, Gilson 322 Pump, Gilson 156 UV Detector; Column: Waters Xbridge 150×50 mm×10 μm; Mobile phase A: H2O with 0.05% NH3—H2O (v %); Mobile phase B: MeCN; Gradient: B from 25% to 55% in 8.8 min, hold 100% B for 2 min; Flow Rate: 25 mL/min; Column Temperature: 30° C.; Wavelength: 220 nm, 254 nm) to give N-[(2S)-3-[7-chloro-6-(oxazol-5-ylmethoxy)-3,4-dihydro-1H-isoquinolin-2-yl]-2-hydroxy-propyl]-2-(cyclobutylamino)pyridine-4-carboxamide (15 mg, 17.2% yield) as a yellow dry powder.

    Article Title: HDAC inhibitors and therapeutic use thereof
    Article Snippet: The residue was purified by preparative HPLC (Instrument: Gilson GX-215, Gilson 322 Pump, Gilson 156 UV Detector; Column: Xtimate C18 150*40 mm*5 μm; Mobile phase A: H2O with NH3—H2O and NH4HCO3 (v %); Mobile phase B: MeCN; Gradient: B from 23% to 53% in 20 min, hold 100% B for 5 min; Flow Rate: 30 mL/min; Column Temperature: 30° C.; Wavelength: 220 nm, 254 nm).

    Article Title: HDAC inhibitors and therapeutic use thereof
    Article Snippet: The crude product was purified by preparative HPLC (Instrument: Gilson GX-281 Liquid Handler, Gilson 322 Pump, Gilson 156 UV Detector; Column: Phenomenex Gemini-NX 75*40 mm*3 μm; Mobile phase A: [water (NH3H2O+NH4HCO3)-ACN]; Mobile phase B: MeCN; Gradient: B from 31% to 61% in 10.5 min, hold 100% B for 2 min; Flow Rate: 30 mL/min; Column Temperature: 30° C.; Wavelength: 220 nm) to afford N-[2-amino-5-(p-tolyl)phenyl]-4-(3-methyl-1-oxo-4,5-dihydro-3H-isothiazol-1-yl)benzamide (45 mg, 70.2% yield) as white solid.

    Article Title: HDAC inhibitors and therapeutic use thereof
    Article Snippet: The residue was purified by preparative HPLC (Instrument: Gilson GX-281 Liquid Handler, Gilson 322 Pump, Gilson 156 UV Detector; Column: Durashell 150×25 mm×5 μm; Mobile phase A: H2O with 0.05% NH3—H2O (v %); Mobile phase B: MeCN; Gradient: B from 39% to 69% in 10 min, hold 100% B for 2.5 min; Flow Rate: 25 mL/min; Column Temperature: 30° C.; Wavelength: 220 nm, 254 nm) to afford N-[2-amino-5-(4-chlorophenyl)phenyl]-4-(methylsulfonimidoyl)benzamide (15.8 mg).

    Article Title: HDAC inhibitors and therapeutic use thereof
    Article Snippet: The residue was purified by preparative HPLC (Instrument: Gilson GX-281 Liquid Handler, Gilson 322 Pump, Gilson 156 UV Detector; Column: Phenomenex Gemini-NX 80×40 mm×3 μm; Mobile phase A: water with 10 mmol NH4HCO3 (v %); Mobile phase B: MeCN; Gradient: B from 27% to 57% in 7.8 min, hold 100% B for 1 min; Flow Rate: 25 mL/min; Column Temperature: about 30° C.; Wavelength: 220 nm, 254 nm) to afford N-[2-amino-5-(2-thienyl)phenyl]-4-(cyclopropylsulfonimidoyl)benzamide (about 61.7 mg).

    High Performance Liquid Chromatography:

    Article Title: Compounds and methods of use
    Article Snippet: The mixture was concentrated under reduced pressure to give a crude product, which was purified by preparative HPLC (Instrument: Gilson GX-281 Liquid Handler, Gilson 322 Pump, Gilson 156 UV Detector; Column: Waters Xbridge 150×50 mm×10 μm; Mobile phase A: H2O with 0.05% NH3—H2O (v %); Mobile phase B: MeCN; Gradient: B from 25% to 55% in 8.8 min, hold 100% B for 2 min; Flow Rate: 25 mL/min; Column Temperature: 30° C.; Wavelength: 220 nm, 254 nm) to give N-[(2S)-3-[7-chloro-6-(oxazol-5-ylmethoxy)-3,4-dihydro-1H-isoquinolin-2-yl]-2-hydroxy-propyl]-2-(cyclobutylamino)pyridine-4-carboxamide (15 mg, 17.2% yield) as a yellow dry powder.

    Article Title: HDAC inhibitors and therapeutic use thereof
    Article Snippet: The residue was purified by preparative HPLC (Instrument: Gilson GX-215, Gilson 322 Pump, Gilson 156 UV Detector; Column: Xtimate C18 150*40 mm*5 μm; Mobile phase A: H2O with NH3—H2O and NH4HCO3 (v %); Mobile phase B: MeCN; Gradient: B from 23% to 53% in 20 min, hold 100% B for 5 min; Flow Rate: 30 mL/min; Column Temperature: 30° C.; Wavelength: 220 nm, 254 nm).

    Article Title: HDAC inhibitors and therapeutic use thereof
    Article Snippet: The crude product was purified by preparative HPLC (Instrument: Gilson GX-281 Liquid Handler, Gilson 322 Pump, Gilson 156 UV Detector; Column: Phenomenex Gemini-NX 75*40 mm*3 μm; Mobile phase A: [water (NH3H2O+NH4HCO3)-ACN]; Mobile phase B: MeCN; Gradient: B from 31% to 61% in 10.5 min, hold 100% B for 2 min; Flow Rate: 30 mL/min; Column Temperature: 30° C.; Wavelength: 220 nm) to afford N-[2-amino-5-(p-tolyl)phenyl]-4-(3-methyl-1-oxo-4,5-dihydro-3H-isothiazol-1-yl)benzamide (45 mg, 70.2% yield) as white solid.

    Article Title: HDAC inhibitors and therapeutic use thereof
    Article Snippet: The residue was purified by preparative HPLC (Instrument: Gilson GX-281 Liquid Handler, Gilson 322 Pump, Gilson 156 UV Detector; Column: Durashell 150×25 mm×5 μm; Mobile phase A: H2O with 0.05% NH3—H2O (v %); Mobile phase B: MeCN; Gradient: B from 39% to 69% in 10 min, hold 100% B for 2.5 min; Flow Rate: 25 mL/min; Column Temperature: 30° C.; Wavelength: 220 nm, 254 nm) to afford N-[2-amino-5-(4-chlorophenyl)phenyl]-4-(methylsulfonimidoyl)benzamide (15.8 mg).

    Article Title: HDAC inhibitors and therapeutic use thereof
    Article Snippet: The residue was purified by preparative HPLC (Instrument: Gilson GX-281 Liquid Handler, Gilson 322 Pump, Gilson 156 UV Detector; Column: Phenomenex Gemini-NX 80×40 mm×3 μm; Mobile phase A: water with 10 mmol NH4HCO3 (v %); Mobile phase B: MeCN; Gradient: B from 27% to 57% in 7.8 min, hold 100% B for 1 min; Flow Rate: 25 mL/min; Column Temperature: about 30° C.; Wavelength: 220 nm, 254 nm) to afford N-[2-amino-5-(2-thienyl)phenyl]-4-(cyclopropylsulfonimidoyl)benzamide (about 61.7 mg).

    Chromatography:

    Article Title: Compounds and methods of use
    Article Snippet: The mixture was concentrated under reduced pressure to give a crude product, which was purified by preparative HPLC (Instrument: Gilson GX-281 Liquid Handler, Gilson 322 Pump, Gilson 156 UV Detector; Column: Waters Xbridge 150×50 mm×10 μm; Mobile phase A: H2O with 0.05% NH3—H2O (v %); Mobile phase B: MeCN; Gradient: B from 25% to 55% in 8.8 min, hold 100% B for 2 min; Flow Rate: 25 mL/min; Column Temperature: 30° C.; Wavelength: 220 nm, 254 nm) to give N-[(2S)-3-[7-chloro-6-(oxazol-5-ylmethoxy)-3,4-dihydro-1H-isoquinolin-2-yl]-2-hydroxy-propyl]-2-(cyclobutylamino)pyridine-4-carboxamide (15 mg, 17.2% yield) as a yellow dry powder.

    Article Title: HDAC inhibitors and therapeutic use thereof
    Article Snippet: The residue was purified by preparative HPLC (Instrument: Gilson GX-215, Gilson 322 Pump, Gilson 156 UV Detector; Column: Xtimate C18 150*40 mm*5 μm; Mobile phase A: H2O with NH3—H2O and NH4HCO3 (v %); Mobile phase B: MeCN; Gradient: B from 23% to 53% in 20 min, hold 100% B for 5 min; Flow Rate: 30 mL/min; Column Temperature: 30° C.; Wavelength: 220 nm, 254 nm).

    Article Title: HDAC inhibitors and therapeutic use thereof
    Article Snippet: The crude product was purified by preparative HPLC (Instrument: Gilson GX-281 Liquid Handler, Gilson 322 Pump, Gilson 156 UV Detector; Column: Phenomenex Gemini-NX 75*40 mm*3 μm; Mobile phase A: [water (NH3H2O+NH4HCO3)-ACN]; Mobile phase B: MeCN; Gradient: B from 31% to 61% in 10.5 min, hold 100% B for 2 min; Flow Rate: 30 mL/min; Column Temperature: 30° C.; Wavelength: 220 nm) to afford N-[2-amino-5-(p-tolyl)phenyl]-4-(3-methyl-1-oxo-4,5-dihydro-3H-isothiazol-1-yl)benzamide (45 mg, 70.2% yield) as white solid.

    Article Title: HDAC inhibitors and therapeutic use thereof
    Article Snippet: The residue was purified by preparative HPLC (Instrument: Gilson GX-281 Liquid Handler, Gilson 322 Pump, Gilson 156 UV Detector; Column: Durashell 150×25 mm×5 μm; Mobile phase A: H2O with 0.05% NH3—H2O (v %); Mobile phase B: MeCN; Gradient: B from 39% to 69% in 10 min, hold 100% B for 2.5 min; Flow Rate: 25 mL/min; Column Temperature: 30° C.; Wavelength: 220 nm, 254 nm) to afford N-[2-amino-5-(4-chlorophenyl)phenyl]-4-(methylsulfonimidoyl)benzamide (15.8 mg).

    Article Title: HDAC inhibitors and therapeutic use thereof
    Article Snippet: The residue was purified by preparative HPLC (Instrument: Gilson GX-281 Liquid Handler, Gilson 322 Pump, Gilson 156 UV Detector; Column: Phenomenex Gemini-NX 80×40 mm×3 μm; Mobile phase A: water with 10 mmol NH4HCO3 (v %); Mobile phase B: MeCN; Gradient: B from 27% to 57% in 7.8 min, hold 100% B for 1 min; Flow Rate: 25 mL/min; Column Temperature: about 30° C.; Wavelength: 220 nm, 254 nm) to afford N-[2-amino-5-(2-thienyl)phenyl]-4-(cyclopropylsulfonimidoyl)benzamide (about 61.7 mg).

    Column Chromatography:

    Article Title: Compounds and methods of use
    Article Snippet: The mixture was concentrated under reduced pressure to give a crude product, which was purified by preparative HPLC (Instrument: Gilson GX-281 Liquid Handler, Gilson 322 Pump, Gilson 156 UV Detector; Column: Waters Xbridge 150×50 mm×10 μm; Mobile phase A: H2O with 0.05% NH3—H2O (v %); Mobile phase B: MeCN; Gradient: B from 25% to 55% in 8.8 min, hold 100% B for 2 min; Flow Rate: 25 mL/min; Column Temperature: 30° C.; Wavelength: 220 nm, 254 nm) to give N-[(2S)-3-[7-chloro-6-(oxazol-5-ylmethoxy)-3,4-dihydro-1H-isoquinolin-2-yl]-2-hydroxy-propyl]-2-(cyclobutylamino)pyridine-4-carboxamide (15 mg, 17.2% yield) as a yellow dry powder.

    Article Title: HDAC inhibitors and therapeutic use thereof
    Article Snippet: The residue was purified by preparative HPLC (Instrument: Gilson GX-215, Gilson 322 Pump, Gilson 156 UV Detector; Column: Xtimate C18 150*40 mm*5 μm; Mobile phase A: H2O with NH3—H2O and NH4HCO3 (v %); Mobile phase B: MeCN; Gradient: B from 23% to 53% in 20 min, hold 100% B for 5 min; Flow Rate: 30 mL/min; Column Temperature: 30° C.; Wavelength: 220 nm, 254 nm).

    Article Title: HDAC inhibitors and therapeutic use thereof
    Article Snippet: The crude product was purified by preparative HPLC (Instrument: Gilson GX-281 Liquid Handler, Gilson 322 Pump, Gilson 156 UV Detector; Column: Phenomenex Gemini-NX 75*40 mm*3 μm; Mobile phase A: [water (NH3H2O+NH4HCO3)-ACN]; Mobile phase B: MeCN; Gradient: B from 31% to 61% in 10.5 min, hold 100% B for 2 min; Flow Rate: 30 mL/min; Column Temperature: 30° C.; Wavelength: 220 nm) to afford N-[2-amino-5-(p-tolyl)phenyl]-4-(3-methyl-1-oxo-4,5-dihydro-3H-isothiazol-1-yl)benzamide (45 mg, 70.2% yield) as white solid.

    Article Title: HDAC inhibitors and therapeutic use thereof
    Article Snippet: The residue was purified by preparative HPLC (Instrument: Gilson GX-281 Liquid Handler, Gilson 322 Pump, Gilson 156 UV Detector; Column: Durashell 150×25 mm×5 μm; Mobile phase A: H2O with 0.05% NH3—H2O (v %); Mobile phase B: MeCN; Gradient: B from 39% to 69% in 10 min, hold 100% B for 2.5 min; Flow Rate: 25 mL/min; Column Temperature: 30° C.; Wavelength: 220 nm, 254 nm) to afford N-[2-amino-5-(4-chlorophenyl)phenyl]-4-(methylsulfonimidoyl)benzamide (15.8 mg).

    Article Title: HDAC inhibitors and therapeutic use thereof
    Article Snippet: The residue was purified by preparative HPLC (Instrument: Gilson GX-281 Liquid Handler, Gilson 322 Pump, Gilson 156 UV Detector; Column: Phenomenex Gemini-NX 80×40 mm×3 μm; Mobile phase A: water with 10 mmol NH4HCO3 (v %); Mobile phase B: MeCN; Gradient: B from 27% to 57% in 7.8 min, hold 100% B for 1 min; Flow Rate: 25 mL/min; Column Temperature: about 30° C.; Wavelength: 220 nm, 254 nm) to afford N-[2-amino-5-(2-thienyl)phenyl]-4-(cyclopropylsulfonimidoyl)benzamide (about 61.7 mg).



    Similar Products

    90
    Gilson Inc hplc detector gilson 156 uv detector
    Hplc Detector Gilson 156 Uv Detector, supplied by Gilson Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/hplc+gilson+156+uv+detector/hplc+gilson/us12264154-11561-15-18
    Average 90 stars, based on 1 article reviews
    hplc detector gilson 156 uv detector - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Gilson Inc hplc instrument gilson 156 uv detector
    Hplc Instrument Gilson 156 Uv Detector, supplied by Gilson Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/hplc+gilson+156+uv+detector/hplc+gilson/us12043607-5331-5-8
    Average 90 stars, based on 1 article reviews
    hplc instrument gilson 156 uv detector - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Gilson Inc hplc gilson 156 uv detector
    Hplc Gilson 156 Uv Detector, supplied by Gilson Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/hplc+gilson+156+uv+detector/hplc+gilson/us12043607-1240-5-8
    Average 90 stars, based on 1 article reviews
    hplc gilson 156 uv detector - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Gilson Inc hplc uv detector gilson 156
    Hplc Uv Detector Gilson 156, supplied by Gilson Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/hplc+gilson+156+uv+detector/hplc+gilson/us11492350-11688-5-8
    Average 90 stars, based on 1 article reviews
    hplc uv detector gilson 156 - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    Image Search Results